Print

AUTOMATED GAS ANALYSER

 

ANOI 5 + CONSOLA

 

The Gas Analyser is a compact and independent equipment used to measure exhaust gases of gasoline vehicles. This is a 5 Gas Analyser CO, CO2, HC, O2 y NOX (optional), and Lambda coefficient.

It is possible to attach a TUR II module, it ia an universal (both gasoline or diesel ) RPM and oil temperature meter.

A 5000 vehicle database is available, you can match manufacturer's values with real exhaust values taken during the tests. Test results can be displayed on a screen, printed or stored in a database.

 

 

TECHNICAL FEATURES

ANOI 5 Measuring chamber:

  • Measuting range:

CO: 0-15% vol Res. 0.001% vol
CO2: 0-20% vol Res. 0.01% vol
HC: 0-2000 ppm vol Res. 1ppm vol
O2: 0-25% vol Res. 0.01% vol
NOx:0-5000 ppm vol Res. 1 ppm vol (Optional)
Lambda:0.5-1.7 Res. 0.001

  • Operation temperature: -12º to 50ºC
  • Measured gas suction:

Nominal flow: ~4.0 l/min.
Drainage flow: ~3 l/min.

  • Condensate discharge: Continuous and automatic
  • Heating time: max 10 minutes .

- Regulations: UNE 82501

ANOI 5 Software:

  1. Wifi ready cabinet for wireless communication with external gadgets (tablet, PDA, etc), from where you can control all software options.
  2. Real time gas data visualisation.
  3. Real time analog or digital oil temperature and RPM values visualisation.
  4. Simultaneous manufacturer's and test's value visualisation, if available.
  5. LAMBDA coefficient visualisation.
  6. Up to 6 tests per vehicle can be stored in RAM.
  7. Data test can be saved in the database.
  8. Data tests saved in the database can be printed or viewed.
  9. Customer, vehicle and test management.
  10. NOX Kit connection available.
  11. TUR II connection available.

 

 

NOx Kit  (optional):

    1. Nominal measurement range : 0 / 5000 ppm
    2. In board filtering: To avoid SOx gas flow effect.
    3. Average life expectancy: 2 years.
    4. Output signal: 0.05 ± 0.01 μA / ppm
    5. Resolution: 1 ppm
    6. temperature range: From -20ºC to +55ºC
    7. Pressuer range: Atmospheric ±10%
    8. Pressure coefficient: 0.01% señal / mBar
    9. Response time at 95ºC: ≤ 5.5 Seconds
    10. Relative humidity Range: 0 - 12 ppm
    11. Typical base line range (Clean air): 0 to 99% without condensates
    12. Maximum zero variation (+20ºC to + 40ºC): Equivalent to 30 ppm
    13. Weight: 32 gr
    14. Storage average life: Six months in CLT container
    15. Storage temperature:Avoid extreme cold or hot exposure.

RPM and Temperature measuring equipment (TUR-II):

    1. RS232 data transmission ready.
    2. Visualization display.
    3. Measuring characteristics:

- Cylinder number selection option.
- Stroke engine number selection option.

    1. Power source: 10 to 28 V DC .
    2. With the vehicle's own battery.
    3. With a stabilized power supply.
    4. Consumption 0.5 A DC
    5. Equipment working room temperature: 5ºC - 40ºC
    6. Dimensions 200x45x100 mm.
    7. Weight: 0.5 kg.
    8. TEMPERATURE CHARACTERISTICS:
    9. Measuting range: from 15ºC to 200ºC
    10. Resolution: 1
    11. - Type of probe: PT100
    12. VOLUTION CHARACTERISTICS:
    13. Range of measures: 300 - 9990 r.p.m.
    14. Resolution: 10

Type of measure : Vibration

 

ACCESSORIES:

- TUR II: Temperature meter and universal rpm counter.

- NOx Kit.

- TERMOFRA: Infra-red thermometer.

 

Saturday the 20th.